Selected company : RUEGER
Home
Sel. Products
Cart
Register
Sales Network
Link
Help
Authentification
Login:
Password :
Forgot your password ?
Products Search
Keywords :
Company :
RUEGER
Internal folder
Your products
Temperature: chemical, petrochemical, industrie
Thermoelectric sensor
Insets
without thermowell
with thermowell
Multipoint
Temperature transmitters
Thermometers
bimetal
Gas pressure
with electrical contacts
Thermo Hybrid
Temperature: particular applications
Diesel
Heating, Ventilation and Air-conditioning
for heating plants
for ice-cold water circuits
Ventilation and air-conditioning ducts
for boiler
Household applications
Thermo Wells, pockets
according to DIN, for Thermo-Sensor S10
according to ISA, for Thermo-Sensor S50
other (tube welded, from the solid)
Pressure: chemical, petrochemical, industrie
low pressure (diaphragm)
with Bourdon tubes
Without Solid Front
Solid Front Execution
differential with electrical contact
Diaphragm Seal / Separator
Pressure Gauge Accessory
Products catalog -
Temperature transmitters
The prices are shown in the currency of the supplier, the prices in your selected currency will be displayed in the purchasing basket.
S95.3Ux2 /134 HART
Price
Head mounted temperature transmitter
Input :
Pt100/0°C,
Thermocouples K,J,N,T,E,R,S,T,B,L,U
Sensor connection type : 2, 3 or 4 wires circuit
Output : 4…20mA HART 2 wire technology
Configurable error current signal :
high alarm value 22 mA,
low alarm value 3.5 mA
with galvanic separation
measuring error : 0.1 °K
Continous sensor and self monitoring :
supply voltage,
monitoring, wire break and corrosion monitoring
Power supply : 24V DC
Ambient temperature : -40°C + 85°C
Execution : ATEX Ex i as option
Please register in order to see prices.
If you click on Configure button, please wait while the configurator loads.
S95.3Ux2 /138 HART SIL2
Price
Head mounted temperature transmitter
SIL2 declaration of conformity (IEC 61508:2000)
Input: Pt100 or thermocouples: K,J,N,T,E,R,S,T,B,L,U
Sensor connection type : 2, 3 or 4 wires circuit
Output : 4…20mA HART 2 wire technology
Configurable error current signal :
high alarm value 22 mA,
low alarm value 3.5 mA
with galvanic separation
measuring error : 0.1 °K
Continous sensor and self monitoring :
supply voltage,
monitoring, wire break and corrosion monitoring
Power supply : 24V DC
Ambient temperature : -40°C + 85°C
Execution : ATEX Ex i as option
Please register in order to see prices.
If you click on Configure button, please wait while the configurator loads.
S95.3Wxx
Price
Head mounted temperature transmitter
Input : Pt100/0°C, Thermocouples K,J,N,T,E,R,S,T,L,U
Input functionality :1 or 2 sensors (e.g. 2 x Pt100 3 wires), Sensor backup/redundancy, Sensor drift monitoring
Sensor connection type : 2, 3 or 4 wires circuit /2x2 wires or 2x 3 wires
Output :
4…20mA HART 2 wires technology with configurable error current signal : high alarm value 22 mA or low alarm value 3.5 mA
or PROFIBUS PA, Profile 3.01
or FONDATION Fieldbus H1, ITK Version 5.1
with galvanic separation
Measuring error : 0.1 °K
Continous sensor and self monitoring : supply voltage monitoring, wire break and corrosion monitoring
Power supply : 24V DC
Ambient temperature : -40°C + 85°C
Options: Execution for SIL2 conformity, ATEX Exi certification, Ambient temperature : -50°C + 85°C
Please register in order to see prices.
If you click on Configure button, please wait while the configurator loads.
S95.4Wxx
Price
Field mounted temperature transmitter
Input : Pt100/0°C, Thermocouples KK,J,N,T,E,R,S,B,T,L,U
Input functionality : 1 or 2 sensors (e.g. 2 x Pt100 3 wires),
Sensor backup/redundancy, Sensor drift monitoring Sensor connection type : 2, 3 or 4 wires circuit / 2x2 wires or 2x 3 wires
Output : 4?20mA HART 2 wires technology, PROFIBUS PA or Fieldbus
Configurable error current signal : high alarm value 22 mA, low alarm value 3.5 mA
Measuring error : 0.1 °K
with galvanic separation
Continous sensor and self monitoring : supply voltage monitoring, wire break and corrosion monitoring
Power supply : 24V DC Ambient temperature : -40°C + 85°C
Housing with or without display : aluminium die cast chromized inside/outside, 70mm, epoxide-coated, gray RAL9002 ; IP66 et IP 67 NEMA 4X or stainless steel
Execution : Execution for SIL2 conformity as option, ATEX Exi or Exd certification as option
Please register in order to see prices.
If you click on Configure button, please wait while the configurator loads.